Skip to main content

Table 5 Distribution of lung function test parameters in 120 rice mill workers by duration of employment

From: Prevalence of respiratory symptoms and disorders among rice mill workers in India

Parameters

Duration of employment (years)

F value

p value

Post hoc multiple comparison tests

N = 47

<10

(mean ± SD)

N = 31

10–19

(mean ± SD)

N = 42

≥20

(mean ± SD)

Comparison

P value

SE

P < 0.05

FVC (l)

4.01 ± 0.14

3.52 ± 0.23

3.10 ± 0.31

167.90

0.000

1 vs. 3

18.3

0.03

Yes

1 vs. 2

9.0

0.03

Yes

2 vs. 3

7.6

0.03

Yes

FEV1 (l)

3.08 ± 0.41

2.81 ± 0.32

2.21 ± 0.19

82.11

0.000

1 vs. 3

12.6

0.04

Yes

1 vs. 2

3.60

0.05

Yes

2 vs. 3

7.82

0.05

Yes

% FEV1/FVC

76.25 ± 3.02

79.14 ± 3.24

72.04 ± 2.84

51.62

0.000

1 vs. 3

9.93

0.50

Yes

1 vs. 2

4.14

0.49

Yes

2 vs. 3

6.57

0.45

Yes

PEFR (l/min)

325.25 ± 29.2

311.05 ± 32.0

300.0 ± 31.0

7.63

0.000

1 vs. 3

3.89

4.59

Yes

1 vs. 2

2.00

5.00

No

2 vs. 3

1.52

5.11

No