Skip to main content

Table 1 Hygienic measurements in the riding-school stable

From: Installation of mechanical ventilation in a horse stable: effects on air quality and human and equine airways

Parameters

Round 1

Round 2

Round 3

Unit

Calculated as:

CO2

 In stable

990 (550–1280)

800 (670–900)

510 (350–750)

ppm

Median (10th–90th percentile)

 Outdoors

360 (350–370)

550 (530–660)

310 (300–350)

ppm

Median (10th–90th percentile)

Ammonia

na

3212

1330

μg/m3

Median

Relative humidity

 In stable

73 (41–84)

79 (65–83)

86 (58–97)

RH%

Mean (range)

 Outdoors

88 (66–94)

76 (43–97)

na

RH%

Mean (range) 

Temperature

 In stable

8 (7–15)

21 (19–24)

8 (6–12)

°C

Mean (range)

 Outdoors

6 (5–10)

21 (19–30)

6 (2–15)

°C

Mean (range)

Total dust

210 (210–790)

220 (100–250)

200 (160–290)

μg/m3

Mean (range)

Respirable dust

100 (60–270)

70 (60–210)

130 (40–410)

μg/m3

Mean (range)

PM10

 In stable

na

53 (34–88)

65 (26–159)

μg/m3

Median (10th–90th percentile)

 Outdoors

na

47 (34–54)

na

μg/m3

Median (10th–90th percentile)

Ultrafine particles

 In stable

8000 (5100–13,000)

1500 (900–1900)

5400 (3000–9000)

Pt/cm3

Median (10th–90th percentile)

 Outdoors

10500 (5500–17,500)

2000 (1600–2600)

4600 (1800–6300)

Pt/cm3

Median (10th–90th percentile)

Horse allergen

5170

750

790

U/m3

Median

Microorganisms surface

 Bacteria (total)

110 (20–140)

1.6 (0.4–2.2)

1.4 (1.0–27)

105/cm2

Median (range) 

 Fungi (total)

6.6 (6.0–8.4)

0.06 (0.04–0.1)

0.15 (0.06–0.15)

105/cm2

Median (range)

Microorganisms air

 Bacteria (total)

19 (0.9–22)

3.2 (0.7–4.7)

21 (21–77)

105/m3

Median (range)

 Bacteria (CFU)

0.7 (0.2–3.6)

0.03 (0.03–0.25)

1.6 (1.6–70)

105/m3

Median (range)

 Fungi (total)

3.5 (0.1–13)

1.5 (1.2–2.7)

6.6 (6.6–22)

105/m3

Median (range)

 Fungi (CFU)

0.2 (0.002–0.96)

0.04 (0.03–0.05)

0.05 (0.05–3.8)

105/m3

Median (range)

Endotoxin air

96

85

275

EU/m3

Median (range)

  1. CFU Colony-forming units, PM 10 particulate matter with a diameter <10 μm, na data not available
  2. Round 1 was carried out during the winter before the intervention—no mechanical ventilation present; Round 2 was carried out during the summer before the intervention—no mechanical ventilation was present; Round 3 was carried out during the winter after the intervention—mechanical ventilation had been installed